Ken Richardson explains how to safely check and lower a boiler's radiator temperature dial to save energy, with checks for condensing boilers and hot water tanks.
Key Takeaways
- Lowering the boiler radiator setting from around 75-80 to about 60 can save money with little loss of comfort for most homes.
- Always confirm the boiler type and whether there is a hot water tank before changing the setting, since a tank may need higher water temperatures.
- Make small adjustments, note the original setting, and monitor the coldest room to find the lowest comfortable temperature.
- Leave complex systems, high or hard-to-reach boilers, and anything requiring the cover to be removed to a qualified engineer.
What the video covers
- A couple, Margaret and Ron, question a 'don't touch' boiler dial setting of 80 that has been left untouched for years.
- Nesta estimates an average home could save around £57 a year by lowering the radiator setting from 75 to 60.
- Two checks come first: whether the boiler is a condensing model (identifiable by a white or grey condensate pipe and a flue plume) and whether the home has a hot water cylinder or heat pump.
- Only the outside controls of a condensing combi boiler should be adjusted; the cover should never be removed and high or awkward boilers should be left to an engineer.
- Users should note the current setting before changing it, reduce the dial gradually (e.g. to 60), and watch the coldest room for signs it is no longer warming up.
- Radiators will feel cooler and mornings may take longer to warm, so starting the heating slightly earlier may help.
- Smart thermostats, app-controlled systems and underfloor heating may already manage temperatures and should be checked with the installer first.
- Some boilers may cycle on and off more often at lower settings; users should note this and consult an engineer if it persists.
- Weather compensation controls can adjust the flow temperature automatically based on outside temperature, a more advanced option than a manual dial.
- Comfort and safety come first: rooms used should remain at least around 18 degrees, and the dial should be turned back up if rooms stay cold.
Chapters
- 00:00Introduction: Margaret and Ron's boiler dial
- 00:51Potential savings from lowering the setting
- 01:35Safety checks: condensing boiler and hot water tank
- 03:03How to adjust the controls safely
- 03:52Recording and changing the setting step by step
- 04:47What to expect and handling cold rooms
- 06:30Smart controls, underfloor heating and closing remarks
Full Transcript — Download SRT & Markdown
Speaker A
Margaret opened the boiler cupboard and reached for the dial. Then she stopped. Right next to it was an old strip of brown parcel tape, and on it, in black marker: "Eighty. Don't touch. R." R was Ron, her husband.
Speaker A
He was in the front room with the crossword. Ron knew boilers, and Ron said don't touch.
Speaker A
So she never had. But she'd started to wonder whether that old rule was costing them money.
Speaker A
And, as it turned out, so had Ron. It was Ron who rang and asked me to come and have a look.
Speaker A
And the answer surprised all three of us. Ron had written eighty on that tape for a reason.
Speaker A
But did that old rule still suit this boiler? That dial sets how hot the water going round your radiators gets, and on a lot of boilers it's set at seventy or eighty.
Speaker A
Nesta, the energy charity, reckons an average home could save around £57 a year by turning it down from seventy-five to sixty. Not every home, mind.
Speaker A
There are boilers where you shouldn't do this yourself. So before we go anywhere near Margaret's dial, here are the two checks that matter.
Speaker A
They take a minute. Check one. Is it a condensing boiler? Most boilers fitted in the last twenty years or so are.
Speaker A
Since the mid two-thousands, nearly every new gas boiler put into a British home has had to be one.
Speaker A
They squeeze extra heat out of their own exhaust, heat that older boilers just sent up the flue.
Speaker A
They do that best when the water coming back from the radiators is cool enough.
Speaker A
There are two clues you can spot without touching anything. Underneath, a condensing boiler has a plastic pipe, usually white or grey, about as thick as your thumb.
Speaker A
It carries away the water the boiler makes, to a drain or out through the wall.
Speaker A
If you've seen my video on boilers stopping in a cold snap, that's the pipe that can freeze.
Speaker A
And on a cold morning, there's usually a white plume coming off the flue outside, like breath on a frosty day.
Speaker A
That's mostly water vapour. It's normal. They're clues, not proof. To be sure, look at the booklet, or put the model name from the front of the boiler into a search.
Speaker A
If it's an older, non-condensing boiler, don't go turning it down. Ask whoever services it. Check two.
Speaker A
Have you got a hot water tank, a cylinder in the airing cupboard? If you have, leave the boiler setting alone for now.
Speaker A
That tank needs the water hot enough to be safe, and on a lot of those systems the same boiler setting heats the tank and the radiators.
Speaker A
That's a job for your engineer, and I'll explain why later on. And if you've got a heat pump, it has its own settings, so ask whoever fitted it.
Speaker A
So the simple version, the one you can do this week, is for a condensing combi boiler.
Speaker A
The kind with no hot water tank, where the hot water comes straight from the boiler when you turn the tap on.
Speaker A
On the front you'll usually see two controls. One has a little radiator symbol. One has a tap.
Speaker A
Today, it's the radiator one. Only ever use the controls on the outside of the boiler, the ones you're meant to use. Never take the cover off.
Speaker A
That's a job for a qualified engineer, not you, and not me on a video.
Speaker A
And if bending down to reach the boiler is a struggle, ask someone to give you a hand. It's a two-minute job for anybody.
Speaker A
Also, if your controls already adjust the radiator water temperature automatically, check with your installer before changing that setting.
Speaker A
And if your boiler's up in the loft, or high in a cupboard you'd need steps for, please don't climb up there for this.
Speaker A
Ask someone who can, or leave it for the engineer's next visit. Two minutes on a ladder isn't worth a fall.
Speaker A
Before you touch it, write down where it is now. A bit of masking tape and a pen is perfect, so you can always put it back.
Speaker A
If it's higher than sixty, try sixty. Some dials show degrees. Some show numbers or dots, or bars on a screen.
Speaker A
If yours doesn't show degrees, the booklet will tell you which mark is about sixty.
Speaker A
Nesta, the charity that ran the big campaign on this, has a free walkthrough on their website that goes through the different kinds of controls.
Speaker A
I'll put the link in the description. Leave your room thermostat where you're comfortable. Then over the next few days, check that the rooms you use still get properly warm.
Speaker A
If they don't, turn the dial back up. Straight away. You never sit in the cold to make a setting work.
Speaker A
Not every boiler has a knob. Some have a little screen with plus and minus buttons, and you press the radiator button first, then go down a few steps.
Speaker A
And some homes have a smart thermostat that talks to the boiler and picks the radiator temperature by itself.
Speaker A
On some of those, the boiler's own setting just becomes the most it's allowed to go up to. On others, the setting lives in the app.
Speaker A
If you've got one of those, look in the app's settings, or ask whoever fitted it, before you change anything on the boiler.
Speaker A
And if you've got wet underfloor heating, it usually runs cooler already, so leave that one to whoever fitted it.
Speaker A
So, worth doing tonight: the two checks. Then, if it's a condensing combi, the dial.
Speaker A
If you're new here, I'm Ken, and there's a new video like this every day through the winter.
Speaker A
Subscribe, and they'll be there waiting for you, without any hunting about. A warm welcome to everyone who's joined since the last one.
Speaker A
And this video's here because of one of you. Under my video about leaving the heating on low all day, somebody wrote that the most important point was the one I'd left out, and guessed it'd be coming.
Speaker A
You guessed right. Thank you. If there's something about your own heating you've always wondered about, put it in the comments. That's where my best ideas come from.
Speaker A
When I told Margaret and Ron all this, they had three worries between them, and I'd bet you've got the same three.
Speaker A
The first one was, "Will it break it?" No. That dial is on the front for a reason.
Speaker A
It's there for you to use. The boiler makers themselves put out videos showing people how to turn it down.
Speaker A
You're not doing anything the boiler wasn't built for. The second one was, "Will the house be cold?" That's the one that matters, so let's take it properly.
Speaker A
The third one was Ron's, and he took his time saying it. "So have I had it wrong all these years?" Now, here's what you'll notice after you turn it down, so nothing worries you.
Speaker A
The radiators will feel cooler to the touch. Warm, not scorching. A lukewarm radiator can be doing exactly the job it's meant to.
Speaker A
The question isn't how hot the radiator feels. It's whether the room gets warm. The house will probably take longer to warm up in the morning.
Speaker A
In the test I'll tell you about in a minute, the living room took about a quarter of an hour longer to get warm on sixty than on eighty.
Speaker A
So if your mornings are slower, start the heating a little earlier. Nesta suggest fifteen to thirty minutes.
Speaker A
Only as much earlier as you need. And the boiler might run for longer at a stretch.
Speaker A
Longer doesn't always mean more gas. It may simply be burning more gently, and getting more out of it.
Speaker A
Like driving at a steady fifty instead of foot down, brake, foot down, all the way down the road.
Speaker A
If every room keeps up nicely on sixty, you can try fifty-five. Give it a few days.
Speaker A
Small steps, not a big jump. And sooner or later, one room starts to lag behind.
Speaker A
It's nearly always the same one. The back bedroom over the garage. The bathroom. The extension with the big window.
Speaker A
That room is telling you something. Usually it's got the smallest radiator for the size of it, or it's the draughtiest.
Speaker A
I did a whole video on testing your radiators with your hand, and this is the same detective work from the other end.
Speaker A
That room sets how low you can go. You don't have to fix it. Just keep the dial a notch above where that room started to struggle.
Speaker A
And write the new setting on your masking tape, with the date. One more thing to keep an eye on.
Speaker A
After you turn it down, listen to the boiler for a day or two. If it keeps firing up for a minute, stopping, then firing up again, over and over, make a note of it.
Speaker A
A lot of boilers are bigger than the house really needs, and at lower settings some of them start doing that.
Speaker A
It doesn't mean you've broken anything. Tell your engineer what you've noticed at the next service.
Speaker A
They can check the cause and whether the heating output needs adjusting. Why does one room give up first?
Speaker A
One reason is that its radiator may be too small for cooler water. A radiator's size is worked out for hot water.
Speaker A
The figure on the box, the heat it gives out, is measured with the water very hot.
Speaker A
Run cooler water through the same radiator and it gives out less heat. Quite a lot less.
Speaker A
On the makers' own charts, a radiator running a good bit cooler can give out only around half of what it says on the box.
Speaker A
So in a room with a generous radiator, that doesn't matter. There was always more than enough.
Speaker A
But in a room where the radiator was only just big enough to start with, cooler water means it can't keep up.
Speaker A
That's not the boiler failing. If an engineer confirms that radiator's too small, a bigger one may help.
Speaker A
That alone doesn't mean you need a new boiler. So why were so many boilers set so hot in the first place? It wasn't daft.
Speaker A
For years, it was right. Those older, non-condensing boilers were built for hot water going out and hot water coming back.
Speaker A
If the water coming back was too cool, the gases inside could start to condense where they shouldn't.
Speaker A
That water is slightly acidic, and in a boiler that isn't built for it, that's bad news. I remember those old boilers well.
Speaker A
Big cast-iron things, floor-standing in the kitchen, or a back boiler behind the gas fire in the front room.
Speaker A
When I was starting out, the old hands would check how hot the water was coming back into the boiler.
Speaker A
If it was coming back too cool, they'd turn the boiler up. "Keep it hot, son, or it'll rot from the inside." And they were right, for those boilers.
Speaker A
I watched more than one of them eaten away inside because somebody had run it too cool for years. A lot of us were trained that way.
Speaker A
And a lot of new boilers got set up the same way, out of habit, long after the boilers had changed. Hot radiators, quick heat, nobody rings up to complain.
Speaker A
And that's when I started to understand Ron's note. Eighty wasn't a number he'd picked out of the air.
Speaker A
There was a time when keeping boilers hot was exactly what we were all told to do.
Speaker A
A condensing boiler catches more of that extra heat when the water comes back cooler, roughly below about fifty-five degrees.
Speaker A
Run the radiators very hot, and it catches less of it. It's not an on-off switch.
Speaker A
It's more that the hotter you run it, the more of that bonus goes out into the street. Eighty degrees going round the radiator in an empty spare room.
Speaker A
You might as well post fivers through next door's letterbox. Now, we've looked at this dial on the channel before.
Speaker A
But what the tests actually found is worth a closer look, because it's not quite what the headlines say.
Speaker A
A few winters ago, Nesta paid for a test at the University of Salford. They've got a full-size house inside a giant lab, a replica of an old Victorian end-terrace with solid brick walls, and they can make the weather outside
Speaker A
whatever they like. They set it to a cold winter's day, left the room thermostat at the same setting, and changed the boiler dial.
Speaker A
Going from eighty down to sixty cut the gas used for heating that house by about 12%. Down to fifty-five, about 16%.
Speaker A
But here's the honest bit. The rooms also ended up a little cooler. About half a degree to a degree.
Speaker A
So not all of that saving was the boiler working better. Some of it was the house sitting a touch cooler.
Speaker A
The researchers say most of it was the boiler. But not all. And it's one house in a lab.
Speaker A
So Nesta worked out what it might mean for an ordinary home over a year.
Speaker A
That's the £57 I mentioned at the start: an average home, a combi turned down from seventy-five to sixty, at this winter's price cap.
Speaker A
A bigger home that uses more gas could save more. A small flat, less. Your own saving could be different.
Speaker A
£57 won't change your life. But it's one dial and two minutes, and that makes it worth checking before another winter's bills arrive.
Speaker A
Then they tried it in the real world. About sixty-one thousand people who used an energy app took part in the trial.
Speaker A
Some got advice on setting their boiler. Others didn't. A one-off email didn't show a clear saving.
Speaker A
Monthly reminders, with a setting for each month, made a small difference. Part of the reason, they think, is that lots of people had already turned their dials down after all the publicity, and not everybody followed the advice.
Speaker A
But one result from that trial I really liked. They asked people whether they felt uncomfortably cold.
Speaker A
And there was no difference between the people who got the advice and the people who didn't. So the lesson for you is simple.
Speaker A
If you're still comfortably warm after turning the dial down, there's no need to nudge the room thermostat up out of habit.
Speaker A
And if you're cold, we put that right first. If you're older, or you're not well, the rooms you use need to be at least eighteen degrees. Comfort first, every time. Right.
Speaker A
The coldest night of the year. On a mild day, your house barely needs any heat, so sixty, or even fifty-five, is plenty.
Speaker A
But when it drops below freezing and stays there for days, the house loses heat much faster, and cooler radiators might not keep up.
Speaker A
So if you set your dial during a mild spell, the first proper freeze is the real test. If the house can't get warm, try five degrees higher.
Speaker A
If the rooms still struggle, turn it up again until you're comfortably warm. Then, when the weather breaks, bring it back down. That's not a failure.
Speaker A
That's using the dial the way it's meant to be used. And it works the other way in spring.
Speaker A
In Nesta's trial, the advice changed through the year: sixty in the depths of winter, fifty-five in March, fifty in April.
Speaker A
As the weather warms up, the house needs less, so the radiators can run cooler still.
Speaker A
Then, when the first cold nights come back in the autumn, go back up to your winter setting before you need it.
Speaker A
A seasonal habit, like changing the clocks, with another adjustment if the weather needs it.
Speaker A
If you're older, or poorly, or on your own, please don't wait to see if the house catches up. Turn it up as soon as the cold comes in.
Speaker A
Warm first, savings second. Some boilers can even do this for you. It's called weather compensation.
Speaker A
A small sensor goes on an outside wall and tells the boiler how cold it is out there. Mild day, cooler radiators.
Speaker A
Freezing night, hotter ones. A lot of boilers can take one, but not all, and not with every control.
Speaker A
So at your next service, just ask, "Can mine take weather compensation?" That was Margaret's big worry, too.
Speaker A
She wasn't going to spend January shivering to save a few pounds. Quite right. So let me show you how it plays out over a whole winter.
Speaker A
This is an example, not a real measurement. Picture a retired couple in an ordinary three-bed semi with a combi boiler.
Speaker A
They're home most of the day. Their dial's been on seventy-five since the boiler went in.
Speaker A
Mid November, a mild spell. They write "seventy-five" on a bit of tape, then turn the dial to sixty.
Speaker A
Thermostat stays on twenty, where they like it. First morning, the front room takes a while longer to feel right.
Speaker A
So they move the timer twenty minutes earlier. After that, they hardly notice. Two weeks later they try fifty-five. The front room's fine. The kitchen's fine.
Speaker A
But the back bedroom, the one over the garage, just won't get there in the evening.
Speaker A
So that's their answer. Back to sixty. New date on the tape. Then December. A week of hard frost, minus four at night.
Speaker A
On the second evening, the front room is stuck at nineteen, and the thermostat's asking for twenty. That's the signal.
Speaker A
Up to sixty-five. Warm again by teatime. When the frost lifts, back down to sixty. That's it.
Speaker A
Five small changes to the boiler dial, each one written on the tape. Nobody sat in the cold.
Speaker A
And they've learned more about their own house than any leaflet could tell them: which room is the weak one, and how hard the boiler really has to work when it's freezing.
Speaker A
And there's a bonus in what they found out, even if they never change their boiler.
Speaker A
Heat pumps work best with cooler water going round the radiators. So if your house stays comfortably warm on fifty-five in a hard frost, that's a good sign your radiators could cope with one one day.
Speaker A
If one room struggles even at sixty-five, get that room checked first. A bigger radiator might help, but it isn't the only possible answer.
Speaker A
It's not a sales pitch. You'd still need a proper survey. But it's free information, from your own house.
Speaker A
If you've found this useful, there's more of it in our book, Warm Home, Lower Bills.
Speaker A
Chapter five is all about this setting. There's a page in it where you can write down your own settings and keep them by the boiler. The book's at kenrichardson.co.uk.
Speaker A
There's also a free printout on the same page, and that costs nothing at all.
Speaker A
That's all I'll say about it. So, homes with a hot water tank. Why I asked you to leave it to the engineer.
Speaker A
I had a call once from a chap in a nineteen-thirties semi. He'd turned his boiler right down to fifty.
Speaker A
Radiators fine, house fine, and he was very pleased with himself. A week later, his wife ran a bath, and it came out barely warm.
Speaker A
His boiler heated the tank and the radiators with the same setting, and on fifty it couldn't get the tank hot.
Speaker A
The lukewarm bath was the bit he noticed. The bit he didn't notice was worse.
Speaker A
Water sitting in a tank needs to get to sixty degrees or more to stop nasty bacteria growing in it.
Speaker A
On that kind of system, the Energy Saving Trust says the boiler setting should be no lower than sixty-five, so it can get the tank to sixty.
Speaker A
So if you've already turned yours down and you've got a tank, put it back to at least sixty-five today, and talk to your engineer.
Speaker A
They can often set it up so the radiators run cooler while the tank still gets hot enough. And never turn the tank's own thermostat below sixty.
Speaker A
And if you've tested your house, and you're warm, and the bills are fine, and you'd rather leave it all alone, that's fine too.
Speaker A
Your house beats any study. Before I tell you what Margaret did, I'd love to hear this one.
Speaker A
Tell me one rule about the heating that somebody in your house laid down years ago, and whether you still stick to it. Everybody's got one.
Speaker A
The right setting is the one that keeps you comfortably warm, without heating the radiator water any hotter than it needs to be. So. Margaret's boiler.
Speaker A
And Ron's tape. I asked them when the boiler was put in. About eight years before, Margaret said.
Speaker A
And before that, they'd had an old one. A big floor-standing boiler in the kitchen that Ron had kept an eye on for twenty-odd years. And that's when it made sense.
Speaker A
For that old boiler, keeping it hot made sense. Ron had learned a sensible rule, and he'd stuck to it.
Speaker A
So when the new boiler went in, he did what he'd always done. He set it high, and he wrote the tape, so nobody would spoil it.
Speaker A
But the new boiler was a condensing one. It had the plastic pipe underneath. On a cold morning, there was a little white plume outside.
Speaker A
But we didn't go on the pipe and the plume alone. We checked the model in the booklet.
Speaker A
A condensing combi, with no hot water tank. So they passed both checks. If they'd had a cylinder in the airing cupboard, I'd have stopped there and told them to ask their engineer.
Speaker A
A boiler built to run cooler, set up by a man who'd looked after his old one properly. I explained all this to Ron.
Speaker A
He thought about it for a minute. And then he said, "So I was right.
Speaker A
Just not any more." Margaret laughed. She said it was the nearest thing to "I was wrong" she'd heard from him in fifty years. So we turned it to sixty.
Speaker A
Ron's hand on the dial, not mine. Their thermostat stayed exactly where it was. And I told them what to do in a cold snap.
Speaker A
Margaret rang me in the new year. The house had been just as warm, she said.
Speaker A
They'd set the timer a little earlier for the mornings. And the gas had come down a bit. Not a fortune. But enough to notice.
Speaker A
And Ron didn't throw his old tape away. He peeled it off the boiler very carefully, and stuck it on the inside of the cupboard door.
Speaker A
Then he wrote a new strip, same marker, same handwriting, and put it where the old one used to be.
Speaker A
"Sixty. R." Keep warm, and look after each other.
Topics:boilerradiator temperatureenergy savingcondensing boilerheating controlshome heatinggas boilerhot water cylinderNestaenergy efficiency